VERSA IP

Control panel

The VERSA IP control panel is designed for protection of small and medium-sized premises. It allows you to create a wired or wireless system, as well as a hybrid one, which combines both these kinds of system. It is compatible with ACU-120 and ACU-270 controllers, which offer an excellent operating range for the ABAX, ABAX 2 family devices – even up to 500 m in the open.

The VERSA IP is the only solution that combines features that were previously only available by using several separate devices. ETHM, INT-VG and INT-AVmodules as well PSTN dialer are integrated on its mainboard. As a result, the VERSA IP control panel enables communication via two channels: Ethernet and PSTN, thus ensuring effective transfer of information.

  • EN50131 Grade 2 compliance
  • 4 programmable wired zones:
    • support for NO and NC type detectors, and roller shutter and vibration detectors
    • support for EOL and 2EOL configuration
  • additional tamper input, NC type
  • 5 programmable wired outputs:
    • 2 high-current outputs
    • 2 high-current outputs, OC type
    • 1 relay output
  • 3 power outputs
  • output for connecting dedicated enclosure-mounted piezoelectric transducer (acoustic signaling)
  • maximum number of programmable zones: 30
  • maximum number of programmable outputs: 12
  • system subdivision into 2 partitions:
    • each zone can be assigned to two partitions
  • system control by means of:
    • LCD or LED keypads
    • VERSA-LCDM-WRL, VERSA-KWRL2 wireless keypads
    • INT-TSG, INT-TSH touchscreen keypads
    • proximity cards
    • remote control keyfobs
  • integrated PSTN module to enable:
    • reporting (SIA, ContactID, etc.)
    • voice messaging (8 numbers, 16 messages)
    • remote programming (300 bps modem) with DLOADX program
  • built-in ETHM module to enable:
    • e-mail messaging
    • control by means of VERSA CONTROL application offering PUSH notifications
    • reporting to monitoring station
    • programming with DLOADX program
  • built-in voice module:
    • nearly 13 minutes for messages to be used in voice menu
    • over 4 minutes for 16 telephone notification messages (with message duration up to 16 seconds)
  • built-in USB-HID socket
  • memory of 2047 events
  • capability to handle 30 users and assign to each of them:
    • code
    • proximity card
    • keyfob
  • 4 timers to enable automatic:
    • arming/disarming partitions
    • control of outputs (turning light ON/OFF, watering garden, etc.)
  • plug-in terminal blocks
  • option of not reporting possible problems with connecting to the SATEL server as a failure.

 

Voice messages  16
Low current programmable outputs rating   50 / 12 VDC mA
Event log     2047
Partitions    2
Timers    4
Power supply rating       2 A
Enclosure dimensions        266 x 286 x 100 mm
Board dimensions              173 x 105 mm
Operating temperature range     -10…+55 °C
Supply voltage (±15%)           18 V AC, 50-60 Hz
Maximum humidity              93±3%
Current consumption from 230 V mains – standby       120 mA
Current consumption from battery – standby               160 mA
Battery failure voltage threshold (±10%)                        11 V
Battery cut-off voltage (±10%)                                     10,5 V
Environmental class according to EN50130-5         II
Maximum current consumption from the 230V network       160 mA
Maximum current consumption from the battery           200 mA
Programmable wired inputs                                                 4
Maximum number of programmable inputs                       30
Programmable wired outputs                                                5
Maximum number of programmable outputs                    12
Supplying outputs                                                                   3
Communication buses                                                         1
Manipulators                                                                    up to 6
Security grade according to EN 50131                    Grade 2
Current-carrying capacity, AUX output            500 / 12 V DC
Recommended transformer                                  40 VA
Mass (incl. enclosure and accessories)                 1220 g
Users                                                                                                 30
Notification e-mail addresses                                                     8
Text messages                                                                                 64
Current-carrying capacity of +VR output                                 200 / 12 V DC
Current-carrying capacity of KPD output                                          500 / 12 V DC
Current-carrying capacity of programmable relay output           1000 / 24 V DC mA
Current-carrying capacity of programmable high-current outputs           1100 / 12 VDC mA
Output voltage range                                                                              10,5 V…14 V DC
Battery charging current                                                                        800 mA
Power supply output voltage                                                            12 V DC ±15%
Telephone numbers for notification                                                   8

VERSA IP

Price
Product card
VERSA IP
Information materials
Catalogue
Technical Data
VERSA end user leaflet
INT-TSH & INT-TSG

Description

Control panel

The VERSA IP control panel is designed for protection of small and medium-sized premises. It allows you to create a wired or wireless system, as well as a hybrid one, which combines both these kinds of system. It is compatible with ACU-120 and ACU-270 controllers, which offer an excellent operating range for the ABAX, ABAX 2 family devices – even up to 500 m in the open.

The VERSA IP is the only solution that combines features that were previously only available by using several separate devices. ETHM, INT-VG and INT-AVmodules as well PSTN dialer are integrated on its mainboard. As a result, the VERSA IP control panel enables communication via two channels: Ethernet and PSTN, thus ensuring effective transfer of information.

  • EN50131 Grade 2 compliance
  • 4 programmable wired zones:
    • support for NO and NC type detectors, and roller shutter and vibration detectors
    • support for EOL and 2EOL configuration
  • additional tamper input, NC type
  • 5 programmable wired outputs:
    • 2 high-current outputs
    • 2 high-current outputs, OC type
    • 1 relay output
  • 3 power outputs
  • output for connecting dedicated enclosure-mounted piezoelectric transducer (acoustic signaling)
  • maximum number of programmable zones: 30
  • maximum number of programmable outputs: 12
  • system subdivision into 2 partitions:
    • each zone can be assigned to two partitions
  • system control by means of:
    • LCD or LED keypads
    • VERSA-LCDM-WRL, VERSA-KWRL2 wireless keypads
    • INT-TSG, INT-TSH touchscreen keypads
    • proximity cards
    • remote control keyfobs
  • integrated PSTN module to enable:
    • reporting (SIA, ContactID, etc.)
    • voice messaging (8 numbers, 16 messages)
    • remote programming (300 bps modem) with DLOADX program
  • built-in ETHM module to enable:
    • e-mail messaging
    • control by means of VERSA CONTROL application offering PUSH notifications
    • reporting to monitoring station
    • programming with DLOADX program
  • built-in voice module:
    • nearly 13 minutes for messages to be used in voice menu
    • over 4 minutes for 16 telephone notification messages (with message duration up to 16 seconds)
  • built-in USB-HID socket
  • memory of 2047 events
  • capability to handle 30 users and assign to each of them:
    • code
    • proximity card
    • keyfob
  • 4 timers to enable automatic:
    • arming/disarming partitions
    • control of outputs (turning light ON/OFF, watering garden, etc.)
  • plug-in terminal blocks
  • option of not reporting possible problems with connecting to the SATEL server as a failure.

 

Voice messages  16
Low current programmable outputs rating   50 / 12 VDC mA
Event log     2047
Partitions    2
Timers    4
Power supply rating       2 A
Enclosure dimensions        266 x 286 x 100 mm
Board dimensions              173 x 105 mm
Operating temperature range     -10…+55 °C
Supply voltage (±15%)           18 V AC, 50-60 Hz
Maximum humidity              93±3%
Current consumption from 230 V mains – standby       120 mA
Current consumption from battery – standby               160 mA
Battery failure voltage threshold (±10%)                        11 V
Battery cut-off voltage (±10%)                                     10,5 V
Environmental class according to EN50130-5         II
Maximum current consumption from the 230V network       160 mA
Maximum current consumption from the battery           200 mA
Programmable wired inputs                                                 4
Maximum number of programmable inputs                       30
Programmable wired outputs                                                5
Maximum number of programmable outputs                    12
Supplying outputs                                                                   3
Communication buses                                                         1
Manipulators                                                                    up to 6
Security grade according to EN 50131                    Grade 2
Current-carrying capacity, AUX output            500 / 12 V DC
Recommended transformer                                  40 VA
Mass (incl. enclosure and accessories)                 1220 g
Users                                                                                                 30
Notification e-mail addresses                                                     8
Text messages                                                                                 64
Current-carrying capacity of +VR output                                 200 / 12 V DC
Current-carrying capacity of KPD output                                          500 / 12 V DC
Current-carrying capacity of programmable relay output           1000 / 24 V DC mA
Current-carrying capacity of programmable high-current outputs           1100 / 12 VDC mA
Output voltage range                                                                              10,5 V…14 V DC
Battery charging current                                                                        800 mA
Power supply output voltage                                                            12 V DC ±15%