INT-E

Zone expansion module

The module is designed for use in conjunction with the control panels of INTEGRA, INTEGRA Plus, VERSA, VERSA Plus, PERFECTA and PERFECTA-T families as well as with ACCO-NT access control panel. This device replaces the CA-64 E/CA-64 EPS module. The INT-E offers expansion of the system by 8 wired zones as well as allows direct connection of roller shutter and vibration detectors. The additional tamper input facilitates detection of unauthorized opening of the enclosure in which the module is installed.

  • system expansion with 8 zones
  • support for:
    • NO, NC
    • EOL, 2EOL/NO, 2EOL/NC (alarm control panels only)
    • 3EOL (INTEGRA Plus only)
  • programmable EOL resistance value (INTEGRA, INTEGRA Plus, VERSA, VERSA Plus only)
  • support for vibration and roller shutter detectors (alarm control panels only)
  • ability to connect to RS-485 bus (firmware update via the bus)

Technical Data
Supply voltage 12 V DC
Operating temperature range -10 °C…+55 °C
Standby mode current consumption 35 mA
Max. current consumption 80 mA
Weight 47 g
Maximum humidity 93±3%
Dimensions 80 x 57 mm
Environmental class according to EN50130-5 II
+12 V output rating 2,5 A / 12 V DC
Security grade acc. to EN 50131 (without power supply) Grade 3
Security grade acc. to EN 50131 (with APS-412 power supply) Grade 2

INT-E

Price
SKU:
Quantity
Product card
Information materials
Technical Data

Description

Zone expansion module

The module is designed for use in conjunction with the control panels of INTEGRA, INTEGRA Plus, VERSA, VERSA Plus, PERFECTA and PERFECTA-T families as well as with ACCO-NT access control panel. This device replaces the CA-64 E/CA-64 EPS module. The INT-E offers expansion of the system by 8 wired zones as well as allows direct connection of roller shutter and vibration detectors. The additional tamper input facilitates detection of unauthorized opening of the enclosure in which the module is installed.

  • system expansion with 8 zones
  • support for:
    • NO, NC
    • EOL, 2EOL/NO, 2EOL/NC (alarm control panels only)
    • 3EOL (INTEGRA Plus only)
  • programmable EOL resistance value (INTEGRA, INTEGRA Plus, VERSA, VERSA Plus only)
  • support for vibration and roller shutter detectors (alarm control panels only)
  • ability to connect to RS-485 bus (firmware update via the bus)

Technical Data
Supply voltage 12 V DC
Operating temperature range -10 °C…+55 °C
Standby mode current consumption 35 mA
Max. current consumption 80 mA
Weight 47 g
Maximum humidity 93±3%
Dimensions 80 x 57 mm
Environmental class according to EN50130-5 II
+12 V output rating 2,5 A / 12 V DC
Security grade acc. to EN 50131 (without power supply) Grade 3
Security grade acc. to EN 50131 (with APS-412 power supply) Grade 2